KS270

Yalın tasarım, kolay kullanım.

Teknik dokümantasyon

Ön Panel

 

(1) ARCforce

(2) Sıcak Başlangıç

(3) Fonksiyon Listesi Seçimi

(4) Fonksiyon Listesi Seçimi

(5) Lift TIG Ateşleme

(6) CEL

Eror Listesi
ERR01Error-1
Phase error. Occurs when any of the phases does not reach the machine.
ERR03Error-3
IGBT thermal error. Occurs when the IGBTs overheat or when the fan is not operating.
(Used in SAW models only.)
ERR04Error-4
Flow sensor error. Triggered when the machine runs out of coolant or when the connectors
are not properly inserted.
ERR05Error-5
IGBT thermal error. Occurs when the IGBTs overheat or the fan is not operating.
ERR06Error-6
Diode thermal error. Triggered when the output diode overheats.
ERR08Error-8
Panel board communication error. Occurs when the panel board fails to communicate
with the motor board.
ERR09Error-9
Motor board communication error. Occurs when the motor board fails to communicate
with the control board.
ERR10Error-10
Con trol board communication error. Triggered when the control board fails
to communicate with the panel.
ERR12Error-12
Overcurrent error. Occurs when the machine attempts to draw excessive current or when
one of the phases is missing.
ERR14Error-14
Overcurrent protection error. Usually triggered by an IGBT malfunction.
ERR15Error-15
It occurs when there is a problem at +15 or -5 volts. It can also trigger this error if the
current sensor is faulty.
ERR20Error-20
Robot board communication error. Occurs when the robot board fails to communicate
with the control board.
ERR30Error-30
Motor overcurrent error. Triggered when the motor current exceeds its defined limit.
ERR40Error-40
Memory read/write error. Occurs when the panel fails to read or write data. When this error
occurs, the panel automatically resets after 5 seconds and attempts to read/write again.
Fabrika Ayarları

F5 butonuna 5 saniye boyunca basılı tutunuz.
Makine ekranda 5’ten 1’e kadar geri sayım yapacaktır. Geri sayım tamamlandığında cihaz otomatik olarak fabrika ayarlarına dönecektir.